At AZAR FIRE SAFETY SYSTEMS L.L.C, we are dedicated to providing cutting-edge fire protection solutions that prioritize safety and efficiency. Our extensive product range includes advanced technologies designed to meet the diverse needs of various industries.
Our Eurosafe Clean Agent Fire Suppression System is UL-listed and utilizes environmentally friendly agents such as HFC227ea and FK5112 (marketed as ES1230) to effectively suppress fires without leaving any residue.
The Foam Deluge System is also UL-listed and provides robust protection against flammable liquid fires, particularly in industrial settings, refineries, and chemical storage areas. Utilizing a foam solution, this system creates a blanket over the fuel source, effectively smothering the fire and preventing re-ignition.
Designed specifically for safeguarding electrical enclosures, our Automatic Electric Control Cabinet Protection System is UL-listed and offers unparalleled protection against fire hazards.
The Euro-X Aerosol Fire Suppression System employs innovative aerosol technology to deliver effective fire suppression across various applications. This compact and efficient solution is suitable for environments where traditional suppression methods may not be feasible. Its quick activation time and minimal clean-up requirements make it an excellent choice for commercial and industrial settings.
Crowcon Flame & Gas Detection System is UL-listed and manufactured by Crowcon, providing reliable detection of flames and hazardous gases such as methane and propane.
This specialized detection system monitors carbon monoxide (CO) and nitrogen dioxide (NO2) levels in parking structures to ensure the safety of both vehicles and occupants. By providing real-time monitoring and alerts, this system helps prevent dangerous gas accumulation in enclosed spaces
Fyreline Linear Heat Detection System is UL-listed and designed to provide continuous monitoring along designated areas, making it ideal for large spaces such as warehouses or tunnels.
This comprehensive system integrates advanced fire detection with efficient extinguishing capabilities, ensuring a rapid response to fire incidents. It combines alarm notifications with automatic suppression mechanisms to protect lives and property effectively.
The Inergen Gas Suppression System utilizes inert gases to suppress fires without harming sensitive equipment or the environment. This eco-friendly solution is ideal for data centers, archives, and other areas where traditional extinguishing agents may pose a risk.
Our CO2 Suppression System is designed for high-risk environments where rapid extinguishment is crucial. It effectively displaces oxygen around the fire source, leading to quick suppression while minimizing damage to surrounding areas.
A Public Announcement (PA) and Voice Evacuation System is a critical component in buildings and facilities, designed to deliver clear and concise messages to occupants during emergencies or routine situations. These systems are often integrated with fire alarm systems and are crucial for managing safe evacuation or providing important updates.
A water mist system is a fire protection system that uses very fine water sprays (i.e. water mist). The small water droplets allow the water mist to control, suppress or extinguish fires.
Deluge Valve, External Resetting Diaphragm Style – 2” thru 12”. Deluge Valves are diaphragm-type valves intended for vertical installation in fire prevention systems.
A water turbine powers the EUROSAFE High Expansion Foam Generators. Depending on the solution flow rate and water pressure, they are designed to expand the foam solution with Expansion ratios of up to 800:1. However, the ideal expansion ratio is in the 500:1 to 700:1 range. The High Expansion Foam Generator does not require any additional power sources such as electricity or gasoline engines. They are propelled by a foam solution that powers a hydraulic (water) motor or turbine. The foam solution is expanded by spraying it over a nylon net/stainless steel screen, then an air stream formed by the motor’s fan blasts air through the screen to produce a mass of foam bubbles. The constant flow of the foam solution, along with the passage of air through the screen, will result in vast quantities of completed foam. Portable systems have their own proportioning system, whereas fixed systems must employ the fixed proportioning system.
Heat, combustibles, and an oxidizing agent, usually oxygen, are required for a fire to ignite. A natural fire will start when all of these ingredients are present and combined properly. The removal of any one of these components can stop or put out a fire. The exothermic chain reaction maintains a fire after it has begun and permits it to spread until or unless at least one of the fire’s components is blocked. By either denying the fire the oxygen it needs to burn, lowering the fuel’s temperature below the ignition point or erecting a barrier of inert gases, traditional fire control techniques address the chemical process that is causing the fire.
Pre-Action Fire Sprinkler System Designed for Water Sensitive Areas That Require Protection from Inadvertent Water Flow into the Sprinkler System Piping.